What is FranklinWH installation training?

FranklinWH installation training consists of training sessions provided by FranklinWH to its installers, through which they are trained to install, commission and maintain the FHP system. Completing the training sessions means that you have been qualified for the installation of FHP products. Your installer account will be authenticated, so that you can activate new products and use the installation tools.

What Is The Operation Temperature Range?

aPower

Environmental Specifications
Operation Temperature Range    -4°F~122°F (-20℃~50℃)
Derated Temperature Range    113°F~122°F (+45℃~50℃)
Recommended Temperature    32°F~86°F(0℃~30℃)


Allowable Storage Temperatures
Storage Duration    Allowable Temperature Range
≤ 24 hours    -22°F~140°F(-30℃~60℃)
≤ 9 months    14°F~113°F(-10℃~45℃)


aGate

Temperature Specifications
Operation Temperature Range    -4°F~122°F(-20℃~50℃)
Storage Temperature Range
-4°F~122°F(-20℃~50℃)
 

The FHP equipment is shut off as air conditioner pump is powered on

Please check the grid power supply.

The grid power supply may not be working properly. The start-up of some high-power equipment, such as air conditioners and water pumps require very large electrical input currents. When high-power equipment is running, starting the water pump or air conditioner may result in unexpected shutdown of aPower. If this occurs, it is recommended to shut down the other high-power equipment and restart them after the water pump or air conditioner has been successfully started and running.